Hi,
On Tue, Sep 29, 2009 at 06:47:26PM +0100, Crankyadmin wrote:
Below is my output of superiotool. Lets use the floppy as a example.
Found Winbond W83627EHF/EF/EHG/EG (id=0x88, rev=0x63) at 0x2e
^^^^ Super I/O config register is 0x2e
Register dump: idx 20 21 22 23 24 25 26 27 28 29 2a 2b 2c 2d 2e 2f val 88 63 ff 00 80 00 00 ff 50 04 00 00 00 21 00 ff def 88 MM ff 00 MM 00 MM RR 50 04 00 RR 00 21 00 00
LDN 0x00 (Floppy)
^^^^ logical device number 0 (== floppy)
idx 30 60 61 70 74 f0 f1 f2 f4 f5
----- -- --
val 00 00 00 06 02 8e 00 ff 00 00 def 01 03 f0 06 02 8e 00 ff 00 00
^^^^^ ^^ ^^ 0x3f0 6 2
How does this turn into this:
devicetree.cb ----->snip<----- device pnp 2e.0 on #floppy
^^^^ This is the config port (without "0x"), then a dot, then the LDN
io 0x60 = 0x3f0
I/O base, in register 0x60 of the Superio LDN 0 (in this case), 16 bit in size, thus it's in 0x60 and 0x61.
irq 0x70 = 6
The IRQ is in register 0x70, value is 6, see above
drq 0x74 = 2
Similar here.
BTW the way these to sets of information are unlikely to match, what I'm trying to collate is how do you get them to match. Any hints would be appreciated
You have to read the superio datasheet to get the correct existing LDNs and their registers/values etc. superiotool -d helps, but reading the respective datasheet is required of course, to make sure everything's OK.