On 09/11/07 13:26 -0700, Myles Watson wrote:
-----Original Message----- From: Jordan Crouse [mailto:jordan.crouse@amd.com]
It will reset once - it shouldn't reset repeatedly (doesn't on my test setup). I haven't tried the public version yet, I'll do that. The issue is on the non-coherent devices - the coherent ones should optimize correctly - if they don't, thats a way bigger problem.
It continuously reset for me. It seems to work fine with a LAB payload with the soft_reset commented out.
what version of SimNow are you using, and what BSD?
I haven't run into the other issues (beside the reset), so I don't know how to test them.
If it boots quickly, then you don't hit the other problem. If the thing grinds to a halt then you hit it.
Maybe that's related to the single reset?
No, it has to do with CAR issues on multiple nodes - you might not hit it if you only have 1 processor x 1 core.