Stefan Reinauer stepan@suse.de writes:
Hi,
does the Solo need any special init for the onboard winbond chip?
Last I checked the Solo has an undocumented PNC chip. But it didn't need anything special to initialize the serial port.
I got the solo target to compile again today, but all I get is reeeaaallyyy slooooow output of the setting up default resources and node1 before it just hangs.
Hmm. Is this perhaps running at 9600 baud.
I believe the speed problem is that the XIP defines have not been picked up in the new configuration stuff. Anyway that is where I would look first for speed problems.
There are enough hard codes in the code at the moment that are smp specifc that we may have a bug there, that can explain the crash.
Eric