Dieter Bloms wrote:
Hi,
On Sat, Jun 16, Stefan Reinauer wrote:
yeah, I got the first readable output from my board. I have configured 9600 Baud in Config.lb and with 19200 in minicom I get these lines:
cool!! What changes were needed?
I've only set the "default TTYS0_BAUD=57600" in the Options.lb file and have to set 115200 in minicom to get the right output.
Sounds like the source or input clock is set wrong.
Try checking/changing CRF0 for UART A clock source settings.
It probably isn't the problem but you could also check CR24 bit 6, 24/48MHz input clock. This is set by a pin on the motherboard but could be wrong or is getting changed?
http://www.winbond-usa.com/products/winbond_products/pdfs/PCIC/W83627HF_HGb....