On 20.11.2007 23:48, Steve Isaacs wrote:
I'm working with a two dual core Opteron (2218HE) motherboard using a new and currently unsupported chipset from Broadcom. During the early startup I'm seeing the messages I've included below. I know I have problems in my Config.lb for the board which is causing the complaint about static devices at the end but my question is regarding the section containing the fidvid timeout messages. Can someone help me out by providing a clue for what I can do to correct the problem?
Thanks,
Steve
LinuxBIOS-2.0.0._xxxx_Fallback OBJ-XXXX-XX Tue Nov 20 14:32:28 PST 2007 starting... (0,1) link=01 (1,0) link=01 02 nodes initialized. core0 started: 01 01 02 03SBLink=00 NC node|link=00 SMBus controller enabled
INIT detected from ---- {APICID = 00 NODEID = 00 COREID = 00} ---
Issuing SOFT_RESET... (0,1) link=01 (1,0) link=03 02 nodes initialized. core0 started: 01 *01*00000001 *02*00000001 *03*00000001 SBLink=00 NC node|link=00 SMBus controller enabled begin msr fid, vid 310a12120a120202 fidvid_bsp_stage1: time out while reading from ap 02 set fid failed for apicid =00 fidvid_bsp_stage2: time out while reading from ap 02 end msr fid, vid 310a120a0a120202 ht reset -
Hm. Just a random thought: Why ap 02 and not 01?
Regards, Carl-Daniel