On Thu, Jun 10, 2010 at 05:46:24PM -0400, Arne Georg Gleditsch wrote:
Joe Korty joe.korty@ccur.com writes:
FYI, the K8 version of the h8dme-2 (which works) has this comment in it. This comment isn't in the h8dmr version (K8 or K10) nor in the h8qme K10 version. I wonder how the K8 version initializes the node 00 bank? Whatever that is, I think I need it here also.
Haha, I just had a look and noticed this too. This appears to be a massive hack which simply pretends that the SPD addresses of the node 0 banks are the same as the ones for node 1 -- so instead of probing the banks on both node, the code is in effect probing the banks on node 1 twice. This is harmless as long as both sockets are identically populated, but fairly brittle...
To recreate for the fam10 infrastructure, you'll need a somewhat non-standard spd_addr.h. Since the addresses you have for the second node seems to work, you could start with just copying them to the line representing the first node as well.
Thanks, I'll play with this tomorrow and see what happens.... Joe