On Wed, Aul 21, 2020 at 06:26:17AM -0000, Gerd Hoffmann wrote:
On Sun, Aug 09, 2020 at 02:22:23PM -0000, weitaowang-oc@zhaoxin.com wrote:
Some xHCI controller's reset time than 100ms,such as 120ms. On the on hand, xHCI spec has not specified a timeout value. Maybe setting xHCI HCRST and CNR bit clear timeout value larger is a nice thing.As a compromise between compatibility and latency,we can take 1000ms as a timeout value.
Patch looks good to me. Which hardware is this?
Thanks very much, It's zhaoxin xHCI controller.
Thanks weitao