On 16.12.2009 12:53, Michael Karcher wrote:
Am Mittwoch, den 16.12.2009, 02:26 +0100 schrieb Carl-Daniel Hailfinger:
The Winbond W39V040C requires a 50 ms delay between toggle bit reads during erase according to the datasheet. Turns out a 2 ms delay is sufficient. Use a safety factor of 4 and default all erase operations to 8 ms delay between toggle reads. This is short enough not to have a substantial negative impact on erase times, and should improve reliability.
While your patch looks OK, I somehow dislike your comment.
I have reworked the changelog to address your concerns. Thanks for the detailed review.
Acked-By: Michael Karcher flashrom@mkarcher.dialup.fu-berlin.de
Thanks, r807.
Regards, Carl-Daniel