Author: quozl Date: Fri Sep 30 02:32:34 2011 New Revision: 2554 URL: http://tracker.coreboot.org/trac/openfirmware/changeset/2554
Log: OLPC XO-1.75 - change LED testing order for C stage since the OLS LED is moving over the storage LED, make the OLS LED flash at a slower rate for better discrimination against what it is near, and turn off the EC OLS gate for both B1 and C1.
Modified: cpu/arm/olpc/1.75/leds.fth
Modified: cpu/arm/olpc/1.75/leds.fth ============================================================================== --- cpu/arm/olpc/1.75/leds.fth Fri Sep 30 02:15:06 2011 (r2553) +++ cpu/arm/olpc/1.75/leds.fth Fri Sep 30 02:32:34 2011 (r2554) @@ -13,11 +13,17 @@ : ols-led-ec-control ( -- ) h# 5b ec-cmd ;
: selftest ( -- ) - ." Flashing LEDs" cr + ." Flashing LEDs" cr + + d# 10 0 do ols-led-on d# 200 ms ols-led-off d# 200 ms loop + ols-led-ec-control + ols-assy-mode-on + " /wlan" test-dev " /wlan" test-dev \ Twice for longer flashing + d# 20 0 do hdd-led-on d# 100 ms hdd-led-off d# 100 ms loop - d# 20 0 do ols-led-on d# 100 ms ols-led-off d# 100 ms loop - ols-led-ec-control + ols-assy-mode-off + confirm-selftest? ;