Attention is currently required from: Shelley Chen, Subrata Banik, Terry Cheong.
Terry Cheong uploaded patch set #7 to this change.
mb/google/brox/var/brox: Enable Class-D calibration
DC offset of class-D amplifier is 7mV in Brox which is larger than the expected 3mV.
Add a section in the verb table to enable class-D calibration based
on the updated verb table provided by Realtek in b:342506575 comment#6.
This improves the offset to be less than 1mV.
BUG=b:342506575
BRANCH=main
TEST=Verify DC offset of speaker amplier output is less than 1mV with a multimeter when \
playing -100dB sine waves.
Change-Id: I776f5c24ce3c829cbd64840957c1431608cf2b85
Signed-off-by: Terry Cheong <htcheong@chromium.org>
---
M src/mainboard/google/brox/variants/brox/include/variant/hda_verb.h
1 file changed, 6 insertions(+), 1 deletion(-)
git pull ssh://review.coreboot.org:29418/coreboot refs/changes/94/82794/7