From my testing on my ProBook 640 G1 (which is using an MEC1322 EC but with the same EC interface), I suggest setting a bigger timeout (I'd like to change it from 0x7ff to 0x10000) in send_kbd_command() and send_kbd_data(), because it can still fail after the first command.